INSTRUMENTATION

EPI 8287 (Industrial)
Trafag
Instrumentation / Primary instrumentation (flow, temperature, level and pressure)

EPI 8287

(Industrial)

The industrial pressure transmitter EPI 8287, like its proven predecessor EPI 8297, features outstanding robustness and a stable sensor cell with a thin steel film. In combination with the new in-house designed ASIC TX, the EPI 8287 covers a wide temperature range up to 125°C. The triple overpressure safety feature makes the EPI 8287 the ideal solution for a wide range of demanding applications.

  • Measuring range: 0 ... 0.2 to 0 ... 600 bar 0... 3 to 0 ... 7500 psi
  • Measuring principle: Thin steel film
  • Accuracy @ 25°C typ.: ±0.5% FS typ. ±0.3% FS typ.
  • Output signal: 4 ... 20 mA, 0 ... 5 VDC, 0.5 ... 5 VDC, 1 ... 6 VDC, 0 ... 10 VDC, 0.5 ... 4.5 VDC radiometric
  • Electrical connections: EN175301-803-A (DIN43650-A); M12x1; Industry standard, contact distance 9.4 mm; Packard Metri Pack; MIL-C 26482; DIN72585; Cable
  • Process connections: G1/4" f; G1/4" m seal; G1/4" m with integrated damping; G1/4" m (manometer) EN 837; G1/2" m (manometer) EN 837; 1/4"NPT m; 1/4"-18NPT f; 1/2"NPT m; R1/4" m, DIN3858; M14x1.5 m, DIN6149-2; 7/16"-20UNF m, DIN3866; 7/16" -20UNF m, SAE4 (J1926); 7/16"-2
  • Media temperature: -40°C ... +125°C
  • Ambient temperature: -40°C ... +125°C Cable PVC: -5°C ... +60°C Cable PUR: -20°C ... +70°C Cable Raychem: -20°C ... +100°C