INSTRUMENTATION
Instrumentation
/
Primary instrumentation (flow, temperature, level and pressure)
EXNA 8854
(Ex)The intrinsically safe pressure transmitter EXNA 8854 is certified to ATEX and IECEx for use in ATEX zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining. Thanks to the wide selection of model variants and pressure ranges from 0.1 to 1000 bar, it can be individually configured for almost any application.
- Measuring range: 0 ... 0.1 to 0 ... 1000 bar
- Measuring principle: Piezoresistive
- Approval/Conformity: DNV-GL Ex to standard, IEC/EN 60079-0/-11/-26, EN 50303
- Output signal: 4 ... 20 mA
- Electrical connections: EN175301-803-A; M12x1; MIL-C 26482; Binder 723; Cable
- Process connections: 1/4"NPT m; 1/2"NPT m; G1/4" f; G1/4" m; G1/2" m; G1/2" m, frontal membrane; G1/2" m, flush membrane
- Media temperature: T3: -40°C ... +150°C T4: -40°C ... +100°C T6: -40°C ... +50°C
- Ambient temperature: T3: -40°C ... +125°C T4: -40°C ... +85°C T6: -40°C ... +50°C